Design data for air pipes

Chose the diameter for the installation

Dimensioning

The right dimensioning of an air pipe is very important: A pressure decrease from 6 bar to 5 bar reduces the power of the machines and tools by up to 25%. If the final compression pressure is increased by 1 bar to compensate for decrease in pressure, costs for operating power increase by 10%.

Pressure decrease 0,1 bar on operating pressure 7 bar. The diagram below allows to determinate the diameter of the main line. By ring line halve the flow rate and the distance.

 
Volumenstrom Gesamtlänge in m = Länge der Rohrleitung + adäquate Rohrlänge für Einbauteile
l/min. cfm 25 40 60 80 100 150 200 250 300 400 500 600 800 1000
400 14,16 15 15 18 18 20 20 22 22 22 25 25 25 28 28
500 17,70 15 18 18 20 20 22 22 25 25 28 28 28 40 40
750 26,55 18 20 20 22 22 25 28 28 28 40 40 40 40 40
1200 42,48 22 22 25 28 28 40 40 40 40 40 40 40 40 50
1500 53,10 22 25 28 40 40 40 40 40 40 40 40 40 50 50
2000 70,80 25 28 40 40 40 40 40 40 40 50 50 50 50 50
3000 106,20 40 40 40 40 40 40 50 50 50 50 50 60 60 60
4800 169,92 40 40 40 50 50 50 50 60 60 60 80 80 80 80
7200 254,88 40 50 50 50 60 60 60 80 80 80 80 80 80 80
10800 382,32 50 60 60 60 80 80 80 80 80 80 80      
15000 531,00 80 80 80 80 80 80 80 80 80          
20000 708,00 80 80 80 80 80 80