Design data for air pipes
Chose the diameter for the installation
Dimensioning
The right dimensioning of an air pipe is very important: A pressure decrease from 6 bar to 5 bar reduces the power of the machines and tools by up to 25%. If the final compression pressure is increased by 1 bar to compensate for decrease in pressure, costs for operating power increase by 10%.
Pressure decrease 0,1 bar on operating pressure 7 bar. The diagram below allows to determinate the diameter of the main line. By ring line halve the flow rate and the distance.
Volumenstrom | Gesamtlänge in m = Länge der Rohrleitung + adäquate Rohrlänge für Einbauteile | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
l/min. | cfm | 25 | 40 | 60 | 80 | 100 | 150 | 200 | 250 | 300 | 400 | 500 | 600 | 800 | 1000 |
400 | 14,16 | 15 | 15 | 18 | 18 | 20 | 20 | 22 | 22 | 22 | 25 | 25 | 25 | 28 | 28 |
500 | 17,70 | 15 | 18 | 18 | 20 | 20 | 22 | 22 | 25 | 25 | 28 | 28 | 28 | 40 | 40 |
750 | 26,55 | 18 | 20 | 20 | 22 | 22 | 25 | 28 | 28 | 28 | 40 | 40 | 40 | 40 | 40 |
1200 | 42,48 | 22 | 22 | 25 | 28 | 28 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 50 |
1500 | 53,10 | 22 | 25 | 28 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 50 | 50 |
2000 | 70,80 | 25 | 28 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 50 |
3000 | 106,20 | 40 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 50 | 60 | 60 | 60 |
4800 | 169,92 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 60 | 60 | 60 | 80 | 80 | 80 | 80 |
7200 | 254,88 | 40 | 50 | 50 | 50 | 60 | 60 | 60 | 80 | 80 | 80 | 80 | 80 | 80 | 80 |
10800 | 382,32 | 50 | 60 | 60 | 60 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | |||
15000 | 531,00 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | |||||
20000 | 708,00 | 80 | 80 | 80 | 80 | 80 | 80 |